Ask Sawal

Discussion Forum
Notification Icon1
Write Answer Icon
Add Question Icon

Krista Dines




Posted Questions


No Question(s) posted yet!

Posted Answers



Answer


AWS Systems Manager Inventory provides visibility into your AWS computing environment. You can use Inventory to collect metadata from your managed nodes.


Answer is posted for the following question.

What is aws inventory?

Answer


An Amazon ECScluster is a logical grouping of tasks or services. Your tasks and services are run on infrastructure that is registered to a cluster.


Answer is posted for the following question.

What is amazon cluster?

Answer


In the process industry, a standard set of symbols are used to prepare piping and instrumentation diagrams (P&IDs). Most of the P&ID drawings you may come across have instrument symbols based on ISA standard S5.1.

The instruction symbol consists of a tag number and identification letter. Numbers on the P&ID symbols in instrumentation diagrams represent instrument tag numbers.

On P&ID drawings, individual instruments are indicated by circular symbols or circle. Shared control/display elements are circles surrounded by a square. Computer functions are indicated by a hexagon and programmable logic controller function are shown as a diamond inside a square.

Adding a single horizontal bar through any of the four graphic elements indicates that the function resides in the main location category. A double line indicates an auxiliary location, and no line places the device or instrument in the field. Devices located behind a panel in some other inaccessible location are shown with a dotted line.

The first letter in the identification letter defines the measured or initiating variables such as:

T - Temperature P - Pressure C - Conductivity I - Current L - Level F - Flow rate A - Analyzer S - Speed J - Power Z - Position V - Vibration H - Hand

The succeeding letters defining functions such as:

E - Element A - Alarm Y - Computation T - Transmitter I - Indicator S - Switch H - High L - Low C - Controller V - Valve F - Fraction

The figure shows, FT 501 is a field mounted flow transmitter connected via electrical signals (dotted lines) to a flow indicator and controller, FIC 501 located in the control room. Please note that a square root extraction of the input signal is applied as part of the functionality of FIC 501.

The output of the FIC 501 is an electrical signal shown in dotted signals is given to an I/P converter TY 501 mounted in the field. The output of TY 501 is a pneumatic signal which acts on the control valve connected to it. The pneumatic signal is shown as a line with pairs of cross lines.

TT 501 and TIC 501 are respectively temperature transmitter and temperature indicator and controller measuring, indicating and controlling temperature. The output of TIC 501 is connected through an internal software or data link (lines with bubbles) to the set point of FIC 501.


Answer is posted for the following question.

What is zsl in p&id?

Answer


Tango Energy

Address: 33 Mackey St, North Geelong VIC 3215, Australia


Answer is posted for the following question.

What are the best energy provider in Geelong, Australia?

Answer


The Barbershop Canberra

Address: Shop 5/54 Marcus Clarke St, Canberra ACT 2601, Australia


Answer is posted for the following question.

Where is the best fades in western Canberra, Australia?

Answer


The evolutionary answer is relatively straightforward: Animals such as snakes and raccoons love to eat turtle eggs To pass on their genes,


Answer is posted for the following question.

Why do turtles live so long?


Wait...