Ask Sawal

Discussion Forum
Notification Icon1
Write Answer Icon
Add Question Icon

Freeman Ironside




Posted Questions


No Question(s) posted yet!

Posted Answers



Answer


It is a measure of the growth of the business or use of the site to sell merchandise owned by others. Gross merchandise value (GMV) is often used to determine the health of an e-commerce site's business because its revenue will be a function of gross merchandise sold and fees charged.


Answer is posted for the following question.

what is gmv growth?

Answer


A huge 45 feet memorial which was built in the memory of Philippine revolutionary Andrés Bonifacio , the founder and Supremo of the Katipunan it was designed by


Answer is posted for the following question.

What is bonifacio monument?

Answer


  1. Start Event Viewer by going to Start > search box (or press Windows key + R to open the Run dialog box) and type eventvwr
  2. Within Event Viewer, expand Windows Logs
  3. Click the type of logs you need to export
  4. Click Action > Save All Events As
  5. Ensure that the Save as type is set to

Answer is posted for the following question.

How to export windows event logs?

Answer


In microbiology, colony-forming unit (CFU, cfu or Cfu) is a unit which estimates the number of microbial cells (bacteria, fungi, viruses etc.) in a sample that are viable, able to multiply via binary fission under the controlled conditions. Counting with colony-forming units requires culturing the microbes and counts only viable cells, in contrast with microscopic examination which counts all cells, living or dead. The visual appearance of a colony in a cell culture requires significant growth, and when counting colonies, it is uncertain if the colony arose from one cell or a group of cells. Expressing results as colony-forming units reflects this uncertainty.

The purpose of plate counting is to estimate the number of cells present based on their ability to give rise to colonies under specific conditions of nutrient medium, temperature and time. Theoretically, one viable cell can give rise to a colony through replication. However, solitary cells are the exception in nature, and most likely the progenitor of the colony was a mass of cells deposited together.[citation needed] In addition, many bacteria grow in chains (e.g. Streptococcus) or clumps (e.g., Staphylococcus). Estimation of microbial numbers by CFU will, in most cases, undercount the number of living cells present in a sample for these reasons. This is because the counting of CFU assumes that every colony is separate and founded by a single viable microbial cell.[1]

The plate count is linear for E. coli over the range of 30 to 300 CFU on a standard sized Petri dish.[2] Therefore, to ensure that a sample will yield CFU in this range requires dilution of the sample and plating of several dilutions. Typically, ten-fold dilutions are used, and the dilution series is plated in replicates of 2 or 3 over the chosen range of dilutions. Often 100µl are plated but also larger amounts up to 1ml are used. Higher plating volumes increase drying times but often don't result in higher accuracy, since additional dilution steps may be needed.[3] The CFU/plate is read from a plate in the linear range, and then the CFU/g (or CFU/mL) of the original is deduced mathematically, factoring in the amount plated and its dilution factor (e.g. CLSI VET01S).

An advantage to this method is that different microbial species may give rise to colonies that are clearly different from each other, both microscopically and macroscopically. The colony morphology can be of great use in the identification of the microorganism present.[citation needed]

A prior understanding of the microscopic anatomy of the organism can give a better understanding of how the observed CFU/mL relates to the number of viable cells per milliliter. Alternatively it is possible to decrease the average number of cells per CFU in some cases by vortexing the sample before conducting the dilution. However many microorganisms are delicate and would suffer a decrease in the proportion of cells that are viable when placed in a vortex.[citation needed]

Concentrations of colony-forming units can be expressed using logarithmic notation, where the value shown is the base 10 logarithm of the concentration.[4][5][6] This allows the log reduction of a decontamination process to be computed as a simple subtraction.

Colony-forming units are used to quantify results in many microbiological plating and counting methods, including:

However, with the techniques that require the use of an agar plate, no fluid solution can be used because the purity of the specimen cannot be unidentified and it is not possible to count the cells one by one in the liquid.[8]

Counting colonies is traditionally performed manually using a pen and a click-counter. This is generally a straightforward task, but can become very laborious and time-consuming when many plates have to be enumerated. Alternatively semi-automatic (software) and automatic (hardware + software) solutions can be used.[citation needed]

Colonies can be enumerated from pictures of plates using software tools. The experimenters would generally take a picture of each plate they need to count and then analyse all the pictures (this can be done with a simple digital camera or even a webcam). Since it takes less than 10 seconds to take a single picture, as opposed to several minutes to count CFU manually, this approach generally saves a lot of time. In addition, it is more objective and allows extraction of other variables such as the size and colour of the colonies.

In addition to software based on traditional desktop computers, apps for both Android and iOS devices are available for semi-automated and automated colony counting. The integrated camera is used to take pictures of the agar plate and either an internal or an external algorithm is used to process the picture data and to estimate the number of colonies. [14][15][16][17]

Many of the automated systems are used to counteract human error as many of the research techniques done by humans counting individual cells have a high chance of error involved. Due to the fact that researchers regularly manually count the cells with the assistance of a transmitted light, this error prone technique can have a significant effect on the calculated concentration in the main liquid medium when the cells are in low numbers.

Completely automated systems are also available from some biotechnology manufacturers.[18][19] They are generally expensive and not as flexible as standalone software since the hardware and software are designed to work together for a specific set-up.[citation needed] Alternatively, some automatic systems use the spiral plating paradigm.[citation needed]

Some of the automated systems such as the systems from MATLAB allow the cells to be counted without having to stain them. This lets the colonies to be reused for other experiments without the risk of killing the microorganisms with stains. However, a disadvantage to these automated systems is that it is extremely difficult to differentiate between the microorganisms with dust or scratches on blood agar plates because both the dust and scratches can create a highly diverse combination of shapes and appearances.[20]

Instead of colony-forming units, the parameters Most Probable Number (MPN) and Modified Fishman Units (MFU)[citation needed] can be used. The Most Probable Number method counts viable cells and is useful when enumerating low concentrations of cells or enumerating microbes in products where particulates make plate counting impractical.[21] Modified Fishman Units take into account bacteria which are viable, but non-culturable.[citation needed]


Answer is posted for the following question.

Why is cfu more applicable to a culture?


Wait...