What is cop for hvac?
What is the Coefficient of Performance? The Coefficient Of Performance (COP) is a performance rating that tells us how effective a heat pump or air conditioner is at transfering heat versus the amount of electrical power it consumes. Remember, heat pumps and air conditioners move heat from a low temperature area, and pump this heat "uphill" to a high temperature area, and against the laws of thermodynamics (Heat Laws), which says that naturally heat flows from something that is hot, to something that is cold. This "uphill" movement of heat from a low temperature area, into a high temperature area, thus requires work, and the COP says how effectively a heat pump or air conditioner performs this work by telling us the amount of power required by the machine to move a certain quantity of heat, at a certain temperature, from a low temperature area to a high temperature area. So, if you've ever wondered how much heat a air conditioner or heat pump can transfer, given a specific amount of power, at a specific temperature, then the COP is what your looking for. COP is typically used to describe a heat pump's heating performance while it's operating in heating mode, however, COP can be used to describe cooling performance for air conditioners as well. For the majority of this article we'll be using examples of the COP for an air source heat pump in heating mode, because as we'll soon find out, a heat pump operating in heating mode has a very high COP, and this make's understanding COP easier. First things first: The COP is a little different from the efficiency labels we have discussed so far. One of the major differences between COP and the other efficiency labels we have talked about so far is the fact that the COP isn't required to be labeled on residential HVAC equipment at all, however, for geothermal heat pumps, or air source heat pumps greater than 5-tons, COP minimum standards are set, which are as follows:
As previously mentioned, minimum COP standards are also set for air source heat pumps with a capacity over 65,000 BTUs/Hr (Greater than 5 Tons), which are heat pump systems that are installed for commercial applications. The minimum requirements are set as follows:
Now, before we continue with the differences between the COP and other efficiency ratings, it's important to note that, although minimum COP standards are only set for geothermal heat pumps and commercial air source heat pumps, this doesn't mean the COP isn't a very useful tool for other types of HVAC systems as well, including the smaller, and more commonly used air source heat pumps and air conditioners like the kind most of us have at home that come in at under 5-tons of capacity. So, even though the COP is not required to be labeled on HVAC equipment, it's still a very useful tool we can and should use to view aan HVAC system's performance with. So, with that being said, let's get back to the differences between COP and other efficiency measurements: If you've been reading through our other articles concerning other efficiency ratings we've discussed thus far, you may have also noticed a few things these other efficiency ratings all had in common with each other, such as a factor of time always being involved. For example: SEER showed us energy efficiency over the course of a cooling season, HSPF showed us energy efficiency over the course of a heating season, and EER could be used to show us energy efficiency over any period of time that we define. Well, the Coefficient Of Performance varies when compared to other efficiency ratings in this way too, because it demonstrates instantanious performance without any factor of time involved. That is to say, the COP tells us exactly how much heat a piece of HVAC equipment transfers when given a specific amount of electrical input power at a specific temperature, and therefore, at a specific and instantanious moment of time, instead of over a period of time like we've seen so far. So when we speak in terms of the Coeffcient of Performance, we are speaking in terms of instantanious performance, which means we speak in terms of power and not energy (Energy is power over time) and more importantly, output power vs input power. Which means, this output power to input power can be expressed as a ratio, and this is exactly what the COP is. COP then, tells us how much heat output power an air conditioner or heat pump transfers versus it's electrical input power. For example: A Heat Pump with a COP of 4:1, or 4, means that for every 1 unit of electrical input power put into the Heat Pump, it provides 4 units of heat output power.
Well, yes, that would be impossible, now wouldn't it? After all, it's a known fact we cannot create something out of nothing, and heat pumps make no exception to this rule, however, what they do may not be magic, but these machines do provide a larger quantity of output heat vs their input quantity of electrical power, and heres why: In order to understand how a heat pump achieves this greater output vs input feat, it's important to remember that: Heat pumps don't create/convert heat out of energy like a furnace does - A heat pump transfers heat from the outdoor environment, and then pumps that heat into a home, which is to say, heat pumps don't create/convert much heat at out of energy at all. It's this concept of transfering thermal energy versus creating/converting thermal energy which dicates that we use the COP to express a machines ability to transfer energy, and thus provide more output than input. When transfering available thermal energy from one area to another, it requires much less energy than it would require to create/convert that same amount of thermal energy out of electricity, or any other fuel source for that matter, which is why we use the COP to express a Heat Pump's ability to transfer heat energy, because it just so happens that they transfer more heat energy than their equivlant input of energy. So, rather than creating thermal energy out of electrical energy (which would imply efficiency), a heat pump simply transfers available thermal energy from the outdoor environment, and uses electrical energy to pump that thermal energy into the home, thus we describe this performance using the COP. This means the COP of Heat Pumps is always greather than 1 and is therefore is a ratio of performance, not a ratio of efficiency, because a machine with an efficiency greater than 1 would imply that the machine is creating something out of nothing, which is impossible. In order to understand COP, it definitely helps to understand how Heat Pumps use electrical power to transfer heat power into our homes, and since the COP typically refers to a heat pump's performance in heating mode, let's go over a quick example with a heat pump so we can see how a heat pumps heat output can be greater than it's electrical input. For example: A heat pump takes electrical input power, and provides heat output power into a home. That is to say, a heat pump uses electrical power to absorb heat from the outdoor environment, raise the temperature of that heat, and transfer this heat into the home, thus warming the home. Heat pumps do this in such a way that since the electrical power used by the heat pump to transfer heat into a home also gets converted into heat, that more output power in the form of heat is being put into the home than the amount of electrical input power being put into the heat pump, which is what makes heat pumps so efficient at what they do - They provide more heat to a home versus the amount of electricity they use because they transfer the available heat energy from the environment, including the heat created by the Heat Pump unit's moving parts, directly into a home. Using the example above: A heat pump uses 1000 Watts of Electrical Power to absorb 3000 Watts of Heat from the Outdoor Environment, and then adds 1000 Watts of Heat to this total, for a combined total of 4000 Watts of Heat being transfered into the home, with only 1000 Watts of Electrical Power actually being used by the heat pump to facilitate this transfer. The COP in this example would be 4:1, or 4, which means for every 1000 Watts of Electrical Input Power being provided to the heat pump, the heat pump transfers 4000 Watts of Heat Output Power into the home, or, 4:1 - Power Out divided by Power In.
Ahh, yes.. It does sound confusing now that we compare apples to apples, especially after learning about SEER, HSPF, and EER, which are all ratios that compared oranges to apples, now doesn't it? But, this is exactly what COP does, which is to say, COP compares two like things: Power Out to Power In, Apples Out to Apples In. However, this doesn't mean we can't simply convert Watts into BTUs/Hr, or into any other form of energy or power that we wish to express the ratio as - As long as we convert both sides of the ratio, we will still have the same percentages of things being compared. Remember: When comparing two percentages of the same type, we can call those two percentages whatever we want, but as long as we don't change the value of the total percentages we are comparing, we are still essentially comparing the same ratio of those things, no matter what we call them. So whether it be a comparison of 50 pennys to 100 pennys, or 2 quarters to 4 quarters, we still end up with half a dollar. Therefore, when it comes to the COP ratio, as long as we convert both the input and output types in the COP equation to the same thing, we are still comparing the same percentage of whatever type we are converting to (Apples to Apples, or Oranges to Oranges, Watts to Watts, BTUs/Hr to BTUs/Hr), and that means we still end up with the same ratio. This means the Coefficient Of Performance (COP) is technically a "dimensionless" ratio of comparison, because it only compares two variables of the same type, and since a machine like a heat pump or air conditioner's electrical input power is commonly measured in Watts, and this information can be easily gathered from equipment data plates and performance records, it's common to express the COP in units of Watts Out to Watts In: However, since Wattage can be converted into BTUs Per Hour (just like quarters can be converted into pennys), after our dimensionless ratio is formed, we can actually use the COP to determine how much heat output in BTUs per Hour a heat pump provides when given a specific amount of electrical power in Watts by taking things a step further, and converting Watts of Output Power to BTUs/Hr: So using our previous example with the Heat Pump that had an electrical input power of 1000 Watts, and a Heat Output Power of 4000 Watts (COP 4:1): If 1 Watt is Equal to 3.413 BTUs/Hr, this means we can easily convert our Heat Pump's Output Power of 4000 Watts into BTUs/Hr by multiplying it by 3.413, which means 4000 Watts of Output Power is equal to 13,652 BTUs/Hr. In terms of COP, this means for every 1000 Watts of Electrical Input Power to our Heat Pump, our Heat Pump Outputs 13,652 BTUs/Hr: Sound familiar? If you remember from one of our previous articles where we talked about EER, BTUs/Hr divided by Watt Hours of Electrical Power Input is actually EER, which is an apples to oranges comparison. This means converting COP to EER, or EER to COP, is easily achieved by converting either ratio's numerator between Watts and BTUs/Hr. Now, as stated earlier it's important to remember that COP is a ratio of instantaneous equipment performance at a specific temperature, but in the above examples no reference to temperature was given, so what gives?
So, our above example didn't list any reference to outdoor or indoor temperatures, but that's because we were just using a COP of 4:1 with a 4000:1000 Watt Heat Pump as an example to explain how the COP works. Real COP values are instantaneous values that represent performance at specific indoor and outdoor temperatures, and they also differ between a heat pumps cooling and heating modes. This means, there are 2 COP values for every heat pump - One COP is for cooling mode performance, while the other is for Heating mode performance. So how about we examine and calculate the COP of a real heat pump and see how these values and temperatures actually affect performance? Now, as stated earlier, unfortunately the COP is not a performance rating that is required to be labeled on residential HVAC equipment in the United States, so you probably won't find COP data listed on the data plates located on the side of your HVAC system's components (we never have!), however, this data is usually listed in product specification data sheets, which can be obtained from equipment manufacturers. The best way to go about getting a product specification sheet for your equipment is to ask your contractor, or by getting in touch with the manufacturer of your HVAC system. Contractors have accounts with manufacturers, and the dealers who sell the manufacturers equipment, and as such an HVAC contractor can easily pull this data for you either by asking their equipment dealers for it, or by accessing a special contractors section of a manufacturers website and pull it themselves. You can also try searching the internet for product specification data sheets for each of your equipment's model numbers, but remember, you'll need the product specification sheet for the entire HVAC system which includes performance data obtained from testing all 3 pieces of equipment and therefore all 3 models numbers from your entire HVAC system, including the: Outdoor unit, indoor coil, and indoor furnace, which can be difficult to locate. If you can't get a product specification sheet for your HVAC system, this limits your scope and percision of the COP data you can obtain. Without a product specification sheet you're essentially limited to converting cooling performance COP from an EER, or calculating seasonal heating performance from HSPF. Cooling performance COP obtained from coverting an EER into a COP will be accurate, however, converting heating performance COP from a seasonal efficiency rating such as HSPF is technically inaccurate, and shows a COP for an entire heating season, which essentially goes against the way COP is supposed to be used as an instantaneous performance rating. Therefore, without a product specification sheet, it's best to stick to calculating the COP of cooling performance from an EER, which is all you need to do if you only have an air conditioner. If you have a heat pump however, it's best to obtain a product specification sheet to see the COP of the system's heating performance, otherwise you're limited to estimating heat performance through various ways. If you have a product specification sheet, the entire systems performance is clearly laid out for you to examine, as shown below in this 3-Ton Trane XR16 Heat Pump System: As you can see, we have highlighted the COP data for this 3-Ton Trane XR16 Heat Pump system's Heating Performance, which shows us 2 COPs for 2 separate outdoor temperatures including a COP of 3.80 at 47°F, and another COP of 2.60 at 17°F:
Correct. There are actually many more, and techinically there is a different COP for every difference in temperature between both the indoor and outdoor environment the system is operated within, however, on this product specification sheet we are only limited to viewing the heating performance data at 2 separate outdoor temperatures, including 47°F and 17°F. So, if you recall from our previous article where we discussed HSPF, these 2 temperatures may look a little familiar to you, that is to say, these temperatures are the required outdoor environment temperatures used in evaluating a systems HSPF efficiency rating. Therfore, these 2 outdoor temperatures of 47°F and 17°F we're used when the system was operated against a single indoor temperature of 70°F in order to calculate HSPF, which is why only 2 COPs are listed. This brings us to an important point: Manufacturers don't have to list this performance data - The FTC (Federal Trade Commission) doesn't require that machine performance data be readily available to the public on a label, and this means you may not be able to obtain it as easily as you might wish you could. Trane, who provided the product specification sheet we used in this article, is one of these manufacturers who doesn't publicly list this information, however, Trane is nice enough to give this performance data to contractors so they can design and sell a Trane HVAC system, and since it correlates with HSPF, this data is also verified.
Unfortunately no, the COP changes and here is why: Heat pumps lose heating output capacity as the difference between the indoor and outdoor temperature increases. Remember, heat pumps "pump" heat from a cold outdoor environment, into a warm indoor environment, and against the natural heat laws of thermodynamics which state that naturally heat flows from something that is hot, to something that is cold, in order to equalize temperature. This action of moving against the natural flow of things requires work, in the same way carrying a bucket filled with heavy rocks up a steep hill and against the natural force of gravity also requires work, except with a heat pump, it's more like carrying a bucket of heat - The greater the difference in temperature between the indoor and outdoor environment, the steeper the hill, and the more work that is required to move the bucket of heat up the hill. That is to say, since a heat pump "lifts" heat "uphill" as it pumps heat into a home, this requires work, and sometimes more work than a compressor can provide, so it's forced to "lift" less heat "uphill". Using the analogy above with the hill and the man carrying heat, we can see: The further the "lift", or the "uphill" distance the heat pump has to face in order to move heat into a home, the more it has to work. Unfortunately, since a compressor can only do so much work, this inevitably means it loses output capacity, and ends up making the load of heat "lighter" in order to continue to move heat up a steeper slope and into the home. So, since the output capacity changes, and the input of electical power changes, so does the COP. /span>
Yeah.. So at this point you may have noticed the COP of Cooling Performance is not listed no matter where you look on this product specification sheet, and this is perfectly normal, as you probably wont find it listed on most product specification sheets because it's actually deceptively listed as an EER and in a BTUs/HR Output divided by Watt Hours Input format, or oranges to apples. Since COP is an apples to apples ratio of Watts of Output divided by Watts of Input, this means, in order to get your air conditioner's or heat pump's COP of cooling performance all you have to do is simply convert the EER into COP, or multiply your EER by .293, which will convert the oranges to apples ratio into an apples to apples ratio of Watts Out divided by Watts In, or COP: Let's go ahead and do this for our 3-Ton Trane XR16 heat pump system to see what our COP for Cooling Performance is: Alright, so our XR16's COP of Cooling Performance comes out to 3.6625:1, which means, for every 1 unit of electrical input power put into the heat pump, it outputs 3.6625 times as much heat. In this case, the heat pump is operating in cooling mode, which means it's transfering the heat outside of the home. As you can see, our heating performance is actually better than our cooling performance, even though the heat pump has a smaller heating capacity output vs it's cooling capacity output. This is the beautiful thing about heat pumps and it happens to be this way because some of the energy the compressor uses to compress and pump refrigerant get's converted into heat, which automatically get's absorbed into the whole heat transfer process and pumped into the house as heat, thus adding to the amount of heat being pumped into the home. Nice. The exact opposite is true in a heat pump's cooling mode (or an air conditioners cooling mode), the heat energy that the compressor adds is a bad thing, and therefore it has to be removed by the heat pump (or air conditioner), which is why you will usually find a greater heating performance from a heat pump when compared to it's cooling performance.
Right! So, what we need to do now is express our COP ratios as Watts of Output divided by Watts of Input. Our COP performance ratings right now simply tell us the difference between the numerator and denominator of our COP ratios. So, let's go ahead and convert things around into useful data. As you can see by examining the Trane XR16's product specification sheet, Trane was also nice enough to do this for us, and they went way out of their way to list the Watts of electrical power used by the compressor, condenser fan, and indoor blower fan when the heat pump is operating in high speed or low speed, and in both heating and cooling modes. Which means, if we wanted, we could simply add all these Wattages of Input from the different componenents up for each mode, and we would then have our Watts of Input, or the bottom half of our COP ratios. However, this may not always be the case, sometimes all you may get is COP, in which case, you'll have to do a little math to determine what your COP actually equates to in terms of Watts Out vs Watts In, so let's go over how this is done. Let's assume Trane didn't give us this information on our product specifications sheet, and all we have are our COP ratios and output capacities in BTUs/Hr, like so:
Alright, so based off what we have above, we essentially have everything we need to express our COP ratios in the Watts Out divided by Watts In format, and even BTUs/Hr Out divided by Watts In format if we wanted, so lets do both! Lets start with the Cooling Performance data: We know by examining the data above our cooling output capacity is 34,200 BTUs/Hr, and by using our COP, we know this output capacity happens to be 3.6625 times larger than the machines input. So, the first thing we should do is convert our BTUs/Hr into Watts/Hr simply by multiplying our output capacity of 34,200 BTUs/Hr by .293, just like we did before: So, our COP for cooling performance is halfway expressed, the numerator (Watts of Output) comes out to 10,020.6 Watts, which is equivilant to 34,200 BTUs/Hr. Let's go ahead and solve for the bottom half of our cooling performance ratio. Now, again, we know that our output is 3.6625 times larger than the machines input, so, all we have to do now is divide our 10,020.6 Watts of Output by our COP of 3.6625, as shown below: Alright! So our COP for Cooling Performance is now complete and the ratio is now expressed as Watts of Output versus Watts of Input. This means, that for every 2,736 Watts of Electrical Power put into the machine, it outputs (transfers) 10,020.6 Watts of Heat, or 34,200 BTUs/Hr for every 2,736 Watts. Nice! So, the same can be done for both ratios of heating performance, one for the 47°F COP, and another for the 17°F COP. Let's see how our heat pumps heating performance stacks up to it's cooling performance based off these temperatures: The first thing we do, is convert our 47°F heating output capacity of 32,400 BTUs/Hr into Watts, like so: This shows us that in heating mode, our heat pump outputs 9493.2 Watts of Heat. Now, all we need to do is divide our output by this temperatures COP of Heating Performance at 3.80: Ok, so we're done with the COP of Heating Performance at 47°F for this system, which comes out to mean that for every 2,498.21 Watts of Electrical Input, the machine Outputs (transfers) 9493.2 Watts of Heat into the home, or 32,400 BTUs/Hr for every 2,498.21 Watts. Let's solve for the last COP of Heating performance at 17°F, which is a scenario where the heat pump takes a huge dive in output capacity at 21,800 BTUs/Hr. Again, the first thing we do is convert our heating output capacity of 21,800 BTUs/Hr into Watts: And now that we have the output successfully converted our machine's Output into Watts, let's divide by the 2.60:1 COP at 17°F for the machines Watts of Input: And there you have it! This ratio translates to meaning that for every 2,456.69 Watts of Electrical Input the heat pump transfers 6,387.4 Watts of heat into our home, or 21,800 BTUs/Hr of Output for every 2,456.69 Watts of Input. Awesome!
Often people ask what they can do if they can't get their hands on a performance specifications sheet, which is a common issue, because for some reason obtaining COP performance data can pretty difficult unless you ask your contractor, and no matter what, it's pretty much always difficult when it comes to getting the COP of heating performance for a heat pump. But! If you just want to gather your cooling performance data for your heat pump, or all you have is an air conditioner at home that only operates in cooling mode, remember all you need is the EER of your entire HVAC system, which you can obtain from one of the official performance directorys listed below:
Remember, an EER is a efficiency rating describing cooling performance! The EER test is performed while the equipment is operated in Cooling Mode, and at an outdoor temperature of 95°F and at an indoor temperature of 80°F. So, although it's very easy to convert an EER into a COP by multiplying the EER by .293, the COP you get out of an EER is only for the system's operation in Cooling Mode, and not in Heating Mode. Also remember: When searching through these directorys it can be very confusing, however, they all give you the option to search by equipment model number, which is usually the best way to go. Just remember, you need the model numbers off each component in your HVAC system, this typically includes 3 different model numbers: One for the outdoor unit, one for the indoor coil, and one more for the indoor furnace. This is because efficiency ratings are evaluated for an entire system during testing procedures, not just individual components, and this includes gathering performance data from each of the components as they function as an entire system. If you'll re-examine the XR16's product specification sheet above, you'll see how the Watts of Electrical Input consisted of Wattage from outdoor and indoor fans amongst other things, which means data was collected from the outdoor unit and the furnace, and this is because performance data is system-wide, not just per piece of equipment. So make sure you have all your model numbers when you search through these directorys! Otherwise, you may find yourself scrolling through a list of 20000+ HVAC systems! Without a product specification sheet, you're always going to have trouble obtaining your heat pump's COP for Heating Performance, because it's simply not listed in these directorys and the information these directorys do list is simply not enough data to figure out what your COP for Heating Performance is. This means your going to be limited to making assumptions and estimates about your heat pump's COP for heating performance, such as:
COP = |Q| W
COP is defined as the relationship between the power (kW) that is drawn out of the heat pump as cooling or heat, and the power (kW) that is supplied to the compressor.
For example:
A given heat pump used for air cooling has a COP = 2. This means that 2 kW of cooling power is achieved for each kW of power consumed by the pump’s compressor.
COP is indicated without units. Therefore, the produced heat and the supplied power employ the same units during COP calculation.
In contrast to COP, COSP (Co-efficient of System Performance) is a description of the total (electrical) energy used by a heat pump in relation to the total work done (cooling or heating) by the pump.
COSP can therefore be defined as the electrical power in kW used to produce 1 kW of cooling.
The terms COP (Coefficient of Performance) and EER (Energy Efficiency Ratio) are both used to describe the heating and cooling efficiency of your air-conditioning unit.
COP is a measurement of the energy efficiency of your air-conditioning unit’s heating performance.
EER is the ratio of a unit’s cooling output relative to its input power.
Together, each measurement indicates the ratio of heating or cooling provided by your air-conditioning unit relative to the amount of electrical input it requires to generate it.
For example, if your air conditioner generates 5kW of heat from 1kW of electrical input, its COP would be 5. If it only generates 2.6kW of heat from 1kW of electricity, the COP would be 2.6.
Similarly, if your air conditioner generates 5kW of cooling from 1kW of electrical input its EER would also be 5 – and if it generated 3.4kW from the same input, the EER would be 3.4.
These unitless measurements are universal, and help you to determine how efficient your equipment is. In simple terms, the higher the COP and EER, the more energy efficient the equipment is.
Energy efficiency is particularly important when deciding which unit to purchase. Not only does a more efficient unit mean cheaper energy bills; it’s also better for the planet, using less energy to produce its heating or cooling output. At Daikin, we’re committed to producing more energy efficient products as part of our pledge to the planet. According to scientific estimates, we have until 2050 to reach net zero, and reverse the effects of climate change. Every energy saving measure we take on our products is not only better for your pocket, but better for the environment, too.
When you choose Daikin to supply your air-conditioning unit, we want you to have complete peace of mind that you’re receiving world-leading technology that meets the highest standards of efficiency.
That’s why Daikin is a certified member of EUROVENT – a prestigious international organisation of manufacturers committed to improving the standards of air conditioning throughout the European market. To support this mission, all EUROVENT members’ products are subject to rigorous testing in independent laboratories.
The terms COP (Coefficient of Performance) and EER (Energy Efficiency Ratio) are both used to describe the heating and cooling efficiency of your air-conditioning unit.
Coefficient of Performance, or COP, is a measure of efficiency for HVAC systems based on their heating output. Every system requires some form of energy input to run the system, but not every system can make the most of the inputted energy to produce greater output. COP is an objective method to measure and compare different HVAC systems.
COP is calculated by dividing the energy output by the energy input. The greater the COP, the more efficient your system is. An HVAC system with a COP of at least 1 is producing more energy than is required to run it.
Put simply, the more efficient your HVAC system is, the more bang you’ll get for your buck! Choosing an efficient HVAC system with a higher COP will help you minimize your monthly heating bills.
The COP for any HVAC system can be found in its technical specifications guide, and it is a powerful tool for comparing and contrasting your options. If price, convenience, installation, and other factors are all comparable across HVAC systems, then COP can be an important tiebreaker in your search.
Heat pumps are currently the only residential heating and cooling options with COP above 1. Dandelion’s geothermal heat pump has a COP of 4, meaning that for every 1 unit of energy inputted, it produces 4 units of energy to heat and cool your home. In contrast, other HVAC systems barely break even at a COP of 1, or, in many cases, they actually consume more energy than they produce.
Energy Efficiency Ratio, or EER, is another measure of efficiency for HVAC systems that’s used for calculating cooling output or AC. In contrast, the term COP is used for measuring heating output.
EER is calculated using the imperial system, and COP is calculated using the metric system, so the values look a little different. However, since both values are unitless ratios, we can easily convert between the two: a COP of 1 is equivalent to an EER of 3.4.